Customization: | Available |
---|---|
Theory: | Autoclave |
Type: | Pressure Steam Sterilization Equipments |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The JM-DV series Desktop Pulsating Vacuum Sterilizers are advanced medical devices designed to provide efficient and reliable sterilization for a variety of instruments and materials.Junmu pulsating vacuum sterilizers are all Class B sterilizers.The unit disinfects and sterilizes the objects with saturated steam, by the means of pulsely exhausting the cold air to clear the efforts from which to the temperature,and make the objects completely drying by the way of vacuum-exhausting and jacket baking.By using the physical characteristics of the pressured saturated steam will releasing plenty of hot while condensing,the unit will keep the sterilizing objects wet and at high temperature in a given time ,which spoils the virus and the spores together, and good sterilizing efforts will be received.These compact units are particularly useful in settings where space is limited, such as dental clinics, laboratories, and small medical practices. The sterilization process involves the use of high-pressure steam in combination with vacuum pulses to ensure thorough penetration and elimination of microorganisms.
Model Technical parameter |
JM-XD20DV
|
JM-XD23DV | JM-XD24DV |
Chamber Volume: | 20 Liters(φ250×350 mm) | 23 Liters(φ250×470 mm) | 24 Liters(φ250×430 mm) |
Max working temperature: | 134ºC±1ºC | 134ºC±1ºC | 134ºC±1ºC |
Max working pressure: | 0.23mpa | 0.23mpa | 0.22mpa |
Adjusted sterilizing temperature range: | 55ºC~134ºC | 55ºC~134ºC | 55ºC~134ºC |
Adjusted timer range: | 1~99mins | 1~99mins | 1~99mins |
Adjusted drying time range: | 1~99mins | 1~99mins | 1~99mins |
Vacuum limit: | -0.08mpa | -0.08mpa | -0.08mpa |
Hot Average: | ≤2ºC | ≤2ºC | ≤2ºC |
Power supply: | AC220V/50HZ |
110V/220V,60HZ/50HZ
|
AC220V/50HZ |
Dimension: | 67*50*45cm | 50.5*71*45cm | 67*50*45cm |
Transport dimension: | 70*58*60cm | 76*56*51cm | 80*58*55cm |
Gross/Net Weight | 54kg/47kg | 65kg/58kg | 60kg/50kg |
Model Technical parameter |
JM-XD35DV
|
JM-XD50DV | Junmu Medical reserve the right for the modification of the dimension and the weight. |
Chamber Volume: | 35Liters | 50 Liters | |
Max working temperature: | 134ºC±1ºC | 134ºC±1ºC | |
Max working pressure: | 0.22mpa | 0.22mpa | |
Adjusted sterilizing temperature range: | 55ºC~134ºC | 55ºC~134ºC | |
Adjusted timer range: | 1~99mins | 1~99mins | |
Adjusted drying time range: | 1~99mins | 1~99mins | |
Vacuum limit: | -0.08mpa | -0.08mpa | |
Hot Average: | ≤2ºC | ≤2ºC | |
Power supply: | AC220V/50HZ | AC220V/50HZ | |
Dimension: | 730×550×510 mm | 770×600×540 mm | |
Transport dimension: | 810×680×650 mm | 880×730×700 mm | |
Gross/Net Weight | 90/73 kg | 112/93 kg |
The core principle behind the operation of a desktop pulsating vacuum sterilizer is the use of steam under pressure combined with vacuum pulses to achieve sterilization. Here's how it works:
Pre-Vacuum Phase: The chamber is evacuated to remove air, creating a vacuum. This step is crucial as it ensures that steam can penetrate all surfaces of the items being sterilized.
Steam Injection: High-pressure steam is introduced into the chamber. The steam rapidly heats the items, killing microorganisms through denaturation of proteins and other cellular components.
Pulsating Phases: The sterilizer alternates between vacuum and steam phases multiple times. This pulsating action ensures that steam reaches even the most difficult-to-access areas, such as lumens and intricate instruments.
Sterilization Phase: The items are held at a high temperature (typically around 134°C) for a set period, ensuring complete sterilization.
Drying Phase: After sterilization, a final vacuum is applied to remove moisture, leaving the items dry and ready for use.
Product Details |
Application Scenarios and Target Users |
Medical and Dental Clinics
Scenario: In medical and dental practices, maintaining a sterile environment is critical to prevent infections and ensure patient safety.
Use Cases:
Sterilization of surgical instruments such as scalpels, forceps, and clamps.
Processing dental tools like drills, probes, and mirrors.
Sterilizing reusable items such as trays, containers, and implantable devices.
Importance: The pulsating vacuum technology ensures that even complex instruments with hinges, joints, or lumens are thoroughly sterilized, reducing the risk of cross-contamination.
Laboratories (Research, Clinical, and Pharmaceutical)
Scenario: Laboratories require sterile equipment to ensure the accuracy of experiments and the safety of personnel.
Use Cases:
Sterilization of glassware like test tubes, petri dishes, and pipettes.
Processing media preparation tools and culture containers.
Sterilizing reusable lab equipment such as forceps, spatulas, and syringes.
Importance: The sterilizer's ability to remove air and penetrate steam into tight spaces ensures that all microbial life, including spores, is eliminated, which is critical for sensitive experiments and drug development.
Pharmaceutical Industry
Scenario: In drug manufacturing, sterility is paramount to ensure product safety and compliance with regulatory standards.
Use Cases:
Sterilization of containers, vials, and caps used for drug packaging.
Processing equipment like mixing blades, filters, and tubing.
Sterilizing tools used in aseptic processing areas.
Importance: The pulsating vacuum sterilizer's drying phase ensures that no moisture remains, which is crucial for maintaining the integrity of pharmaceutical products.
Veterinary Clinics
Scenario: Veterinary practices require sterilization of instruments to prevent the spread of infections among animals and between animals and humans.
Use Cases:
Sterilization of surgical tools used in animal surgeries.
Processing grooming tools and diagnostic equipment.
Sterilizing reusable items like syringes and needles.
Importance: The sterilizer's efficiency and reliability help maintain high standards of animal care and hygiene.
Beauty and Tattoo Parlors
Scenario: These settings require sterilization of tools to prevent infections and ensure client safety.
Use Cases:
Sterilization of tattoo needles, piercing tools, and razors.
Processing reusable beauty tools like tweezers and scissors.
Importance: The sterilizer's compact design and rapid cycle times make it ideal for small businesses that need quick turnaround times.
Food and Beverage Industry
Scenario: Sterilization is essential in food processing to ensure product safety and extend shelf life.
Use Cases:
Sterilization of packaging materials and containers.
Processing tools and equipment used in food preparation.
Importance: The sterilizer's ability to handle heat-resistant materials ensures compliance with food safety regulations.
Metal Instruments
Examples: Scalpels, scissors, forceps, clamps, and surgical trays.
Challenges Addressed: The pulsating vacuum ensures steam penetrates hinges, joints, and crevices, which are difficult to sterilize using conventional methods.
Glassware
Examples: Test tubes, petri dishes, beakers, and media bottles.
Challenges Addressed: The vacuum phase removes air pockets, ensuring even heat distribution and preventing breakage due to trapped air.
Textiles
Examples: Surgical gowns, drapes, towels, and fabric wraps.
Challenges Addressed: The drying phase removes moisture, preventing the growth of microorganisms and ensuring the textiles are ready for immediate use.
Rubber and Plastic Items
Examples: Catheters, tubing, syringes, and silicone molds.
Challenges Addressed: The sterilizer's precise temperature control prevents melting or deformation of heat-sensitive materials.
Lumened Instruments
Examples: Endoscopes, cannulas, and dental handpieces.
Challenges Addressed: The pulsating vacuum ensures steam penetrates narrow lumens and channels, which are prone to harboring microorganisms.
Heat-Resistant Packaging Materials
Examples: Vials, ampoules, and containers used in pharmaceuticals and food packaging.
Challenges Addressed: The sterilizer's ability to handle high temperatures ensures complete sterilization without compromising the integrity of the packaging.
Reusable Tools and Equipment
Examples: Lab spatulas, forceps, and mixing blades.
Challenges Addressed: The sterilizer's efficiency reduces downtime, allowing for quick turnaround of tools in high-demand environments.
Junmu desktop pulsating vacuum sterilizers are indispensable in a variety of settings due to their ability to handle diverse objects and meet stringent sterilization requirements. Their compact design, combined with advanced vacuum and steam technology, makes them ideal for medical, dental, laboratory, pharmaceutical, veterinary, and even beauty and food industry applications. By understanding the specific scenarios and objects they are designed for, users can optimize their sterilization processes, ensuring safety, compliance, and efficiency.