Advanced Class B Dental Autoclave for Efficient Sterilization
Contact Supplier
Product Highlights
- Class B Sterilization: Advanced pulsating vacuum technology ensures thorough sterilization for all instrument types.
- 1-Year Warranty: Covers parts and labor for 12 months from the date of purchase.
- Built-in Printer: Records full sterilization procedure details for traceability and compliance.
- Bowie & Dick Test: Built-in function to verify steam penetration and air removal efficiency.
- Multi-Capacity Options: Available in 20L, 23L, 24L, 35L, and 50L chamber volumes.
- Comprehensive Safety: Features safety locking, over-pressure protection, and low water protection.
- Online Technical Support: Engineers available for remote assistance and troubleshooting.
- CE, FDA, ISO13485: Certified for international medical standards and safety compliance.
Product Attributes
- Customization
- Available
- Theory
- Autoclave
- Type
- Pressure Steam Sterilization Equipments
- Model NO.
- JM-XD24DV
- Certification
- CE, FDA, ISO13485
- Electric Tension
- 220V
- LCD Display
- With LCD Display
- Ultra High Temperature Alarm
- Ultra High Temperature Alarm
- Sterilization Information Recording and Printing
- Optional
- Material
- Stainless Steel
- Voltage
- 220V
- Key Selling Points
- Easy to Operate
- Warranty
- 1 Year
- Working Temperature
- 134℃
- After-Sale Service
- Online Technical Support
- Capacity
- 20L-50L
- Max Working Pressure
- 0.23MPa
- Hot Average
- ≤±2℃
- Gross/Net Weight
- 54kg/47kg
- Vacuum Limit
- -0.08MPa
- Transport Package
- Customized Packing or Wooden Box
- Specification
- 67*50*45cm
- Trademark
- Junmu
- Origin
- Henan
- HS Code
- 8419200000
- Production Capacity
- 5000
Product Images of Advanced Class B Dental Autoclave for Efficient Sterilization
Find Similar Products
Product Description
The JM-DV series Desktop Pulsating Vacuum Sterilizers are advanced medical devices designed to provide efficient and reliable sterilization for a variety of instruments and materials.Junmu pulsating vacuum sterilizers are all Class B sterilizers.The unit disinfects and sterilizes the objects with saturated steam, by the means of pulsely exhausting the cold air to clear the efforts from which to the temperature,and make the objects completely drying by the way of vacuum-exhausting and jacket baking.By using the physical characteristics of the pressured saturated steam will releasing plenty of hot while condensing,the unit will keep the sterilizing objects wet and at high temperature in a given time ,which spoils the virus and the spores together, and good sterilizing efforts will be received.These compact units are particularly useful in settings where space is limited, such as dental clinics, laboratories, and small medical practices. The sterilization process involves the use of high-pressure steam in combination with vacuum pulses to ensure thorough penetration and elimination of microorganisms.
Characteristics
1. The sterilizing procedure is automatically controlled, it is not necessary to be supervised, and used conveniently.
2. At lease 3 or more times pulse-vacuum exhausting, which is applied to wrapped or unwrapped objects,hollow equipment.
3. Drying function.
4. With inner printer, which record the for the full procedure of the sterilization.
5. With Bowie&Dick testing function, which is for the steam penetrating testing.
6. Self-testing malfunction, easy to maintain.
7. Safety functions:
Safety locking: the steam can not enter the chamber and the unit will alarm when the door is not closed tightly,and the door can not the open when the inner pressure is exceed 0.027mpa.
Over pressure protection:If the pressure exceed the working pressure, the safety valve will exhausting the air.
Low water protection: The unit can not be started if the water don't reach the high level,and the power will cut off directly.
Over current protection: The broker will cut off the power by the over current happened.
| Model Technical parameter |
JM-XD20DV
|
JM-XD23DV | JM-XD24DV |
| Chamber Volume: | 20 Liters(φ250×350 mm) | 23 Liters(φ250×470 mm) | 24 Liters(φ250×430 mm) |
| Max working temperature: | 134ºC±1ºC | 134ºC±1ºC | 134ºC±1ºC |
| Max working pressure: | 0.23mpa | 0.23mpa | 0.22mpa |
| Adjusted sterilizing temperature range: | 55ºC~134ºC | 55ºC~134ºC | 55ºC~134ºC |
| Adjusted timer range: | 1~99mins | 1~99mins | 1~99mins |
| Adjusted drying time range: | 1~99mins | 1~99mins | 1~99mins |
| Vacuum limit: | -0.08mpa | -0.08mpa | -0.08mpa |
| Hot Average: | ≤2ºC | ≤2ºC | ≤2ºC |
| Power supply: | AC220V/50HZ |
110V/220V,60HZ/50HZ
|
AC220V/50HZ |
| Dimension: | 67*50*45cm | 50.5*71*45cm | 67*50*45cm |
| Transport dimension: | 70*58*60cm | 76*56*51cm | 80*58*55cm |
| Gross/Net Weight | 54kg/47kg | 65kg/58kg | 60kg/50kg |
| Model Technical parameter |
JM-XD35DV
|
JM-XD50DV | Junmu Medical reserve the right for the modification of the dimension and the weight. |
| Chamber Volume: | 35Liters | 50 Liters | |
| Max working temperature: | 134ºC±1ºC | 134ºC±1ºC | |
| Max working pressure: | 0.22mpa | 0.22mpa | |
| Adjusted sterilizing temperature range: | 55ºC~134ºC | 55ºC~134ºC | |
| Adjusted timer range: | 1~99mins | 1~99mins | |
| Adjusted drying time range: | 1~99mins | 1~99mins | |
| Vacuum limit: | -0.08mpa | -0.08mpa | |
| Hot Average: | ≤2ºC | ≤2ºC | |
| Power supply: | AC220V/50HZ | AC220V/50HZ | |
| Dimension: | 730×550×510 mm | 770×600×540 mm | |
| Transport dimension: | 810×680×650 mm | 880×730×700 mm | |
| Gross/Net Weight | 90/73 kg | 112/93 kg |
JM-XD23DV JM-XD20DV/JM-XD24DV JM-XD35DV/JM-XD50DV
Application Principles
The core principle behind the operation of a desktop pulsating vacuum sterilizer is the use of steam under pressure combined with vacuum pulses to achieve sterilization. Here's how it works:
-
Pre-Vacuum Phase: The chamber is evacuated to remove air, creating a vacuum. This step is crucial as it ensures that steam can penetrate all surfaces of the items being sterilized.
-
Steam Injection: High-pressure steam is introduced into the chamber. The steam rapidly heats the items, killing microorganisms through denaturation of proteins and other cellular components.
-
Pulsating Phases: The sterilizer alternates between vacuum and steam phases multiple times. This pulsating action ensures that steam reaches even the most difficult-to-access areas, such as lumens and intricate instruments.
-
Sterilization Phase: The items are held at a high temperature (typically around 134°C) for a set period, ensuring complete sterilization.
-
Drying Phase: After sterilization, a final vacuum is applied to remove moisture, leaving the items dry and ready for use.
| Product Details |
The sterilizer is a safe,reliable and automatic control of small fast table sterilization equipment.Items such as food that can with stand the action of saturated steam provide rapid sterilization.
Vacuum degree up to -0.8mpa, suitable for all kinds of packed, unpacked, solid.Full computer control, modular simple operation interface. BOWIE&DICK test for steam penetration.
LCD display working status, touch button.Ensure efficient removal of air inside hollow instruments (such as high-speed dental drill phones) so that high-temperature steam can fully reach every corner.
Application Scenarios and Target Users |
Application Scenarios
-
Medical and Dental Clinics
-
Scenario: In medical and dental practices, maintaining a sterile environment is critical to prevent infections and ensure patient safety.
-
Use Cases:
-
Sterilization of surgical instruments such as scalpels, forceps, and clamps.
-
Processing dental tools like drills, probes, and mirrors.
-
Sterilizing reusable items such as trays, containers, and implantable devices.
-
-
Importance: The pulsating vacuum technology ensures that even complex instruments with hinges, joints, or lumens are thoroughly sterilized, reducing the risk of cross-contamination.
-
-
Laboratories (Research, Clinical, and Pharmaceutical)
-
Scenario: Laboratories require sterile equipment to ensure the accuracy of experiments and the safety of personnel.
-
Use Cases:
-
Sterilization of glassware like test tubes, petri dishes, and pipettes.
-
Processing media preparation tools and culture containers.
-
Sterilizing reusable lab equipment such as forceps, spatulas, and syringes.
-
-
Importance: The sterilizer's ability to remove air and penetrate steam into tight spaces ensures that all microbial life, including spores, is eliminated, which is critical for sensitive experiments and drug development.
-
-
Pharmaceutical Industry
-
Scenario: In drug manufacturing, sterility is paramount to ensure product safety and compliance with regulatory standards.
-
Use Cases:
-
Sterilization of containers, vials, and caps used for drug packaging.
-
Processing equipment like mixing blades, filters, and tubing.
-
Sterilizing tools used in aseptic processing areas.
-
-
Importance: The pulsating vacuum sterilizer's drying phase ensures that no moisture remains, which is crucial for maintaining the integrity of pharmaceutical products.
-
-
Veterinary Clinics
-
Scenario: Veterinary practices require sterilization of instruments to prevent the spread of infections among animals and between animals and humans.
-
Use Cases:
-
Sterilization of surgical tools used in animal surgeries.
-
Processing grooming tools and diagnostic equipment.
-
Sterilizing reusable items like syringes and needles.
-
-
Importance: The sterilizer's efficiency and reliability help maintain high standards of animal care and hygiene.
-
-
Beauty and Tattoo Parlors
-
Scenario: These settings require sterilization of tools to prevent infections and ensure client safety.
-
Use Cases:
-
Sterilization of tattoo needles, piercing tools, and razors.
-
Processing reusable beauty tools like tweezers and scissors.
-
-
Importance: The sterilizer's compact design and rapid cycle times make it ideal for small businesses that need quick turnaround times.
-
-
Food and Beverage Industry
-
Scenario: Sterilization is essential in food processing to ensure product safety and extend shelf life.
-
Use Cases:
-
Sterilization of packaging materials and containers.
-
Processing tools and equipment used in food preparation.
-
-
Importance: The sterilizer's ability to handle heat-resistant materials ensures compliance with food safety regulations.
-
Objects of Sterilization
-
Metal Instruments
-
Examples: Scalpels, scissors, forceps, clamps, and surgical trays.
-
Challenges Addressed: The pulsating vacuum ensures steam penetrates hinges, joints, and crevices, which are difficult to sterilize using conventional methods.
-
-
Glassware
-
Examples: Test tubes, petri dishes, beakers, and media bottles.
-
Challenges Addressed: The vacuum phase removes air pockets, ensuring even heat distribution and preventing breakage due to trapped air.
-
-
Textiles
-
Examples: Surgical gowns, drapes, towels, and fabric wraps.
-
Challenges Addressed: The drying phase removes moisture, preventing the growth of microorganisms and ensuring the textiles are ready for immediate use.
-
-
Rubber and Plastic Items
-
Examples: Catheters, tubing, syringes, and silicone molds.
-
Challenges Addressed: The sterilizer's precise temperature control prevents melting or deformation of heat-sensitive materials.
-
-
Lumened Instruments
-
Examples: Endoscopes, cannulas, and dental handpieces.
-
Challenges Addressed: The pulsating vacuum ensures steam penetrates narrow lumens and channels, which are prone to harboring microorganisms.
-
-
Heat-Resistant Packaging Materials
-
Examples: Vials, ampoules, and containers used in pharmaceuticals and food packaging.
-
Challenges Addressed: The sterilizer's ability to handle high temperatures ensures complete sterilization without compromising the integrity of the packaging.
-
-
Reusable Tools and Equipment
-
Examples: Lab spatulas, forceps, and mixing blades.
-
Challenges Addressed: The sterilizer's efficiency reduces downtime, allowing for quick turnaround of tools in high-demand environments.
-
Junmu desktop pulsating vacuum sterilizers are indispensable in a variety of settings due to their ability to handle diverse objects and meet stringent sterilization requirements. Their compact design, combined with advanced vacuum and steam technology, makes them ideal for medical, dental, laboratory, pharmaceutical, veterinary, and even beauty and food industry applications. By understanding the specific scenarios and objects they are designed for, users can optimize their sterilization processes, ensuring safety, compliance, and efficiency.