Basic Info.
Type
Pressure Steam Sterilization Equipments
Certification
CE, FDA, ISO13485
LCD Display
Without LCD Display
Ultra High Temperature Alarm
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Optional
Voltage
1.5kw/AC 220V 50Hz
Key Selling Points
Easy to Operate
Working Temperature
134ºC
After-Sale Service
Online Technical Support
Max Working Pressure
0.22MPa
Gross/Net Weight
20/18 Kg
Sterilizing Plate
340*200*30 mm
Transport Package
Customized Packing or Wooden Box
Specification
56*35*50 cm
Product Description
Junmu Supply T24J Desktop Top Steam Sterilizers
Product Description
The JM-T24J Desktop Steam Sterilizer is safely auto-controlled, which is designed for the dental clinics, hospitals, school lab, scientific research institutions and laboratory. And mostly suitable for sterilizing of surgical, dental and eye instruments, glassware medicine,culture medium and biological dressing, food, etc.
Characteristics
1.Sterilizing course: Automatic sterilization controlled by computer, easy to operate.
2.Maximum temperature: up to 134 ºC, suit for 4-6 minutes rapidly sterilizing.
3.Safe protection of water lacking.
4.With over-temperature, over-pressure auto-protect device
5.After sterilization it will automatically cut the power and then alarm.
6.Fully stainless steel structure.
Product Parameters
Model Technical parameter | JM-T24J |
Sterilizing chamber volume | 24L(φ270×410 mm) |
Maximum working pressure | 0.22Mpa |
Maximum working temperature | 134ºC |
Adjustment of temperature | 105-134ºC |
Timer | 0-60 min |
Chamber temperature equal | ≤ ± 1ºC |
Source power | 1.5KW/AC 220V 50Hz |
Sterilizing plate | 340×200×30 mm (3 pieces) |
Dimension | 560×350×500 mm |
Package dimension | 620×410×570 mm |
G. W/N.W | 20/18 kg |
Benefits Over Larger Systems
Cost-Effectiveness: Lower upfront investment, energy use, and maintenance vs. industrial autoclaves.
User-Friendly: Minimal training required; ideal for facilities without dedicated sterilization staff.
Scalability: Multiple units can be deployed for high-throughput needs without occupying excessive space.
Limitations & Considerations
Capacity Constraints: Unsuitable for large/bulky items (e.g., full surgical trays).
Material Compatibility: Some plastics or heat-sensitive materials may require alternative methods (e.g., ethylene oxide).
Microcomputer display working status, touch button. The sterilization chamber is made of high quality stainless steel. Handwheel open door Safety valve and Manual vent valve
Application Scenarios and Target Users |
Junmu T24J desktop steam sterilizer is indispensable for ensuring sterility across healthcare, research, and industrial applications. Its versatility, efficiency, and compact design make it a practical choice for small- to medium-scale sterilization needs. Application Scenarios
Medical and Dental Clinics
Scenario: In medical and dental practices, maintaining a sterile environment is critical to prevent infections and ensure patient safety.
Use Cases:
Sterilization of surgical instruments such as scalpels, forceps, and clamps.
Processing dental tools like drills, probes, and mirrors.
Sterilizing reusable items such as trays, containers, and implantable devices.
Importance: The pulsating vacuum technology ensures that even complex instruments with hinges, joints, or lumens are thoroughly sterilized, reducing the risk of cross-contamination.
Laboratories (Research, Clinical, and Pharmaceutical)
Scenario: Laboratories require sterile equipment to ensure the accuracy of experiments and the safety of personnel.
Use Cases:
Sterilization of glassware like test tubes, petri dishes, and pipettes.
Processing media preparation tools and culture containers.
Sterilizing reusable lab equipment such as forceps, spatulas, and syringes.
Importance: The sterilizer's ability to remove air and penetrate steam into tight spaces ensures that all microbial life, including spores, is eliminated, which is critical for sensitive experiments and drug development.
Pharmaceutical Industry
Scenario: In drug manufacturing, sterility is paramount to ensure product safety and compliance with regulatory standards.
Use Cases:
Sterilization of containers, vials, and caps used for drug packaging.
Processing equipment like mixing blades, filters, and tubing.
Sterilizing tools used in aseptic processing areas.
Importance: The pulsating vacuum sterilizer's drying phase ensures that no moisture remains, which is crucial for maintaining the integrity of pharmaceutical products.
Veterinary Clinics
Scenario: Veterinary practices require sterilization of instruments to prevent the spread of infections among animals and between animals and humans.
Use Cases:
Sterilization of surgical tools used in animal surgeries.
Processing grooming tools and diagnostic equipment.
Sterilizing reusable items like syringes and needles.
Importance: The sterilizer's efficiency and reliability help maintain high standards of animal care and hygiene.
Beauty and Tattoo Parlors
Scenario: These settings require sterilization of tools to prevent infections and ensure client safety.
Use Cases:
Importance: The sterilizer's compact design and rapid cycle times make it ideal for small businesses that need quick turnaround times.
Food and Beverage Industry
Scenario: Sterilization is essential in food processing to ensure product safety and extend shelf life.
Use Cases:
Importance: The sterilizer's ability to handle heat-resistant materials ensures compliance with food safety regulations.
Objects of Sterilization
Laboratory Supplies
Glassware (beakers, flasks, pipettes)
Plasticware (centrifuge tubes, microplates)
Stainless steel instruments (forceps, spatulas)
Medical & Surgical Tools
Textiles & Linens
Liquids & Media
Biohazard Waste
This product detail page is designed to provide comprehensive information about the Junmu desktop steam sterilizers.
For specific customization or additional details, please contact our sales team.Our Advantages